Main Advantages |
1. Purpose : Fireproof filling compound for cable¡¯s penetration part
2. This product is made of epoxy material with good elasticity and easy to cut. 3. Provides excellent fire prevention performance. |
---|---|
Feature |
1. Provides excellent smoke-proofing, thermal insulation, and sound insulation.
2. Excellent for filling gaps with elasticity. |
Specification |
900MM*600MM*75T
900MM*600MM*50T |
Pipe size, location, and type | Cable penetration part floor | Pipe size, location, and type | Cable penetration part wall |
---|---|---|---|
Filling material | AG-EC101 (75mm) | Filling material | AG-EC101 (75mm) |
Fire prevention sealant | AG-1119 thickness on both sides 3T | Fire prevention sealant | AG-1119 thickness on both sides 3T |
Location of construction | Top and bottom construction | Location of construction | Double-sided construction |
Structure grade | C-2 (Lightweight foam concrete wall for 2 hours) | Structure grade | A-2 (Lightweight Steel Structural Walls for 2 hours) |
Main Advantages |
1. The neutral hardening type of silicon material provides excellent durability/cold resistance/noise effect.
2. Excellent contraction and expansion capability, long-term sealing performance and excellent fire protection. 3. Used for equipment penetration materials (cables, pipes, ducts, etc.) that penetrate the fire prevention compartment. |
---|---|
Feature |
1. It is liquid and can be sealed perfectly even in curved areas.
2. More than 20 years of durability with silicone material. |
Volume | 300ml |
---|---|
Color | Black, gray |
Surface curing time | Around 15 minutes |
Total curing time | 7~14 days |
Maximum elongation | 500~600% |
Expiration date | 12 months (When stored at room temperature) |
Curing form | 20~25 (Shore A) |
Tensile strength | 10~15 kgf/§¨ |
Specific gravity | 1.32¡¾0.03g/§¨ |
Main Advantages |
1. Used as the main material for refractory filling structures of cable trays, metal pipes, and ducts.
2. Reliable and excellent heat shielding performance even at ultra-high temperatures above 1000¢ªC 3. Strong heat insulation effect blocks heat in case of fire, preventing secondary fire and preventing fire from spreading. 4. Using only proven raw materials, stable and uniform product performance. |
---|---|
Specific |
13T*300MM*14.4M
13T*600MM*14.4M |
Main Advantages |
1. Can transfer a lot of energy from the same volume of conductors.
2. Very economical by minimizing energy loss. 3. Because it is assemblable, wiring can be done according to the construction process, and construction period can be reduced. 4. Vibration and fire resistant, flexible with loading, less electromagnetic waves, and recyclable. |
---|
Pipe size, location, and type | Busduct penetration part floor | Pipe size, location, and type | Busduct penetration part wall |
---|---|---|---|
Filling material | AGF911(75mm) | Filling material | AGF911(75mm) |
Fire prevention sealant | AG-1119 thickness on both sides 3T | Fire prevention sealant | AG-1119 thickness on both sides 3T |
Hermal insulation material | AG-400(25t*400mm) | Hermal insulation material | AG-400(25t*400mm) |
Location of construction | Top and bottom construction | Location of construction | Double-sided construction |
Structure grade | C-2 (Lightweight foam concrete wall for 2 hours) | Structure grade | A-2 (Lightweight Steel Structural Walls for 2 hours) |
Test Result No. | TPP-2019-003797 | Test Result No. | TPP-2019-003798 CFEL-K-2020-00688-1 |