BUSINESS > Equipment

Equipment




Foam Sleeve (AG-FS119)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Specification 75A*150H/180H/210H
100A*150H/180H/210H
125A*150H/180H/210H
150A*150H/180H/210H
200A*150H/180H/210H
Application PP + Fire-Resistant Foam
Performance In the event of a fire, it expands approximately 30 times to block heat and smoke completely.
1. No additional refractory material insertion and no breakage or fall-out.
2. Penetration sleeve self-foaming expansion safety in case of fire.
3. No additional construction cost due to fireproof filler construction and sleeve installation.
4. 50A Using Non-isolated Systems.
Instruction




Video








Foam Drain Cap
(AG-FS007)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Specification 75A Sleeve Insertion Type
Application PP + Fire-Resistant Foam
Performance In the event of a fire, it expands approximately 30 times to block heat and smoke completely.
1. Role of drain trap in case of pipe leak.
2. Application of kitchen, bathroom, laundry room, pipe shaft room, etc.
3. To block the unpenetrated area of the pipe.

Instruction




Video








Fireproof Board (AG-111)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Specification 1200mm*500mm*0.5mmT
Application Galvanized Iron Plate 0.5T * Thermal Expansion Sheet 5T
Performance In the event of a fire, it expands approximately 30 times to block heat and smoke completely.
1. Good workability. (External finish only)
2. No construction defect. (Visually identifiable)
3. Pipe penetration square perforation possible.
4. Easy to handle when modifying, supplementing, or changing penetrating materials for facilities.
Instruction


Video








Steel fixture for steel pipe
(AG-ST1000)


Steel fixture 1. Very sturdy because the fixture is made of a whole steel plate.
2. Oblique net shape on the inner band to prevent slipping.
3. Can be applied to both steel pipe and PVC.
Special painting using steel
(Electro painting)
1. Nonflammable, no poison gas generated because it is water-based paint.
2. Applied to automobile painting. Boasts of high salt, corrosion, and water resistances derived from efficient application.
Convenient construction 1. Fastening bolts are fixed; only nuts should be fastened.
2. All nuts have the same specification. (fixture and sleeve)
Product Groups


Application Metallic pipe (STS, SU, SR, cast-iron pipe, copper pipe, etc.), PVC pipe
Specification SU pipe : 20A, 25A, 30A, 40A, 50A, 60A, 75A, 80A, 100A
Steel pipe .: 15A, 20A, 25A, 32A, 40A, 50A, 65A, 80A, 100A, 125A, 150A
PVC pipe : 25A, 35A, 40A, 50A, 65A, 75A, 100A, 125A, 150A




ABS fixture for PVC
(AG-PF1000)


Feature 1. A fire-retardant, self-extinguishing product.
2. Can be applied to both steel pipe and PVC.
3. Boasts of excellent impact/heat resistances.
4. Large pipe should be installed using bolts on both sides.
5. Small pipe should be installed using bolt on one side.
6. Slipping prevention applied inside of the fixture. (company logo is carved)
7. Thicker and higher compared to those of rival companies.
Convenient construction 1. Fastening bolts are fixed; only nuts should be fastened.
2. Piping purpose is indicated by clamp color.
3. Can be installed regardless of eccentricity.
4. Installation method varies according to the pipe diameter.
Product Groups


Application PVC pipe
Specification 25A, 35A, 40A, 50A, 65A, 75A, 100A




Video








Fire-resistant filling material for steel pipe
(AG-ST110)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Feature 1. Fire prevention foam pad depth 50T + Thermal expansion tape thickness 2T.
2. Provides excellent fire prevention for contraction/expansion.
3. Semi-permanent elastic body that absorbs all external shock.
4. Can be installed easily due to elastic material.
5. Provides excellent soundproofing.
6. Applied to steel pipe less than 100A.
7. Applied to penetration sleeve less than 150A.
8. Components : Fireproof Filling Compound+Fire Prevention Sealant+Thermal Insulation Material.
Product Groups


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Pipe size, location, and type 100A Floor Steel Pipe
Pipe size, location, and type 100A Wall Steel Pipe
Filling material AG-ST110 (50mm)
Filling material AG-ST110 (50mm)
Fire prevention sealant AG-1119 thickness 3T
Fire prevention sealant AG-ST119 thickness on both sides 3T
Thermal insulation material AG-400(25t*200mm)
Thermal insulation material AG-400(25t*200mm)
Location of construction One-side top construction
Location of construction Double-sided construction
Structure grade C-2 (Lightweight foam concrete wall for 2 hours)
Structure grade A-2 (Lightweight Steel Structural Walls for 2 hours)








Fire-resistant filling material for steel pipe
(AG-ST120)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Feature 1. Fire prevention foam pad depth 75T + Thermal expansion tape thickness 2T.
2. Provides excellent fire prevention for contraction/expansion.
3. Semi-permanent elastic body that absorbs all external shock.
4. Can be installed easily due to elastic material.
5. Provides excellent soundproofing.
6. Applied to steel pipe more than 125A, 150A.
7. Applied to penetration sleeve more than 200A.
8. Components : Fireproof Filling Compound+Fire Prevention Sealant+Thermal Insulation Material.
Product Groups


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Pipe size, location, and type 150A floor steel pipe
Pipe size, location, and type 150A wall steel pipe
Filling material AG-ST120(75mm)
Filling material AG-ST100(50mm)
Fire prevention sealant AG-1119 thickness 3T
Fire prevention sealant AG-1119 thickness on both sides 3T
Thermal insulation material AG-400(25t*400mm)
Thermal insulation material AG-400(25t*300mm)
Location of construction One-sided top construction
Location of construction Double-sided construction
Structure grade C-2 (Lightweight foam concrete wall for 2 hours)
Structure grade C-2 (Lightweight foam concrete wall for 2 hours)








Fire-resistant filling material for steel pipe
(AG-ST130)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Feature 1. Fire prevention foam pad depth 50T + Thermal expansion tape thickness 5T.
2. Provides excellent fire prevention for contraction/expansion.
3. Semi-permanent elastic body that absorbs all external shock.
4. Can be installed easily due to elastic material.
5. Provides excellent soundproofing.
6. Applied to steel pipe more than 200A.
7. Applied to penetration sleeve more than 200A.
8. Components : Fireproof Filling Compound+Fire Prevention Sealant+Thermal Insulation Material
Product Groups


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Pipe size, location, and type 400A floor steel pipe
Pipe size, location, and type 400A wall steel pipe
Filling material AG-ST130(50mm)
Filling material AG-ST230(50mm) filling on both sides
Fire prevention sealant AG-1119 thickness 3T
Fire prevention sealant AG-1119 thickness on both sides 3T
Thermal insulation material AG-400 (bottom 25T*400mm 2 layers) /
(top 25T*400mm 1 layers)
Thermal insulation material AG-400(38T*400mm)
Location of construction Top construction
Location of construction Double-sided construction
Structure grade C-2 (Lightweight foam concrete wall for 2 hours)
Structure grade A-2 (Lightweight Steel Structural Walls for 2 hours)








Fire-resistant filling material for PVC wall
(AG-PF210)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Feature 1. Fire prevention foam pad depth 50T + Thermal expansion tape thickness 11T.
2. Provides excellent fire prevention for contraction/expansion.
3. Semi-permanent elastic body that absorbs all external shock.
4. Can be installed easily due to elastic material.
5. Foamed 20-30 times in the event of fire. (penetration part is sealed)
6. Provides excellent soundproofing.
7. Applied to PVC pipe less than 200A. (to be tested for 300A)
8. Components : Fireproof Filling Compound+Fire prevention sealant.
Product Groups


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Pipe size, location, and type 100A floor PVC
Pipe size, location, and type 150A floor PVC
Filling material AG-PF210(50mm)
Filling material AG-PF210(50mm)
Fire prevention sealant AG-1119 thickness 3T
Fire prevention sealant AG-1119 thickness on both sides 3T
Thermal insulation material X
Thermal insulation material X
Location of construction One-sided top construction
Location of construction One-sided top construction
Structure grade C-2 (Lightweight foam concrete wall for 2 hours)
Structure grade C-2 (Lightweight foam concrete wall for 2 hours)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Pipe size, location, and type/th> 200A floor PVC
Pipe size, location, and type 300A floor PVC (To be tested)
Filling material AG-PF210(50mm)
Filling material (To be tested)
Fire prevention sealant AG-1119 thickness 3T
Fire prevention sealant (To be tested)
Thermal insulation material X
Thermal insulation material (To be tested)
Location of construction Top and bottom construction
Location of construction (To be tested)
Structure grade C-2 (Lightweight foam concrete wall for 2 hours)
Structure grade (To be tested)








Fire-resistant filling material for granular PVC
(AG-PW230)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Feature 1. Fire prevention foam pad depth 75T+Thermal expansion tape 6T.
2. Provides excellent fire prevention for contraction/expansion.
3. Semi-permanent elastic body that absorbs all external shock.
4. Can be installed easily due to elastic material.
5. Foamed 20-30 times in the event of fire. (penetration part is sealed)
6. Provides excellent soundproofing.
7. Applied to PVC pipe less than 100A.
8. Components : Fireproof Filling Compound+Fire Prevention Sealant.








Fire-resistant filling material for granular PVC
(AG-PW210)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Feature 1. Fire prevention foam pad depth 75T+Thermal expansion tape 6T.
2. Provides excellent fire prevention for contraction/expansion.
3. Semi-permanent elastic body that absorbs all external shock.
4. Can be installed easily due to elastic material.
5. Foamed 20-30 times in the event of fire. (penetration part is sealed)
6. Provides excellent soundproofing
7. Applied to PVC pipe less than 200A. (to be tested for 300A)
8. Components : Fireproof Filling Compound+Fire Prevention Sealant


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Pipe size, location, and type 100A wall PVC
Pipe size, location, and type 200A wall PVC
Filling material AG-PW230(50mm)
Filling material AG-PW210(50mm)
Fire prevention sealant X
Fire prevention sealant AG-1119 thickness on both sides 3T
Thermal insulation material X
Thermal insulation material X
Location of construction One-sided construction
Location of construction Double-sided construction
Structure grade A-2(Lightweight Steel Structural Walls for 2 hours)
Structure grade A-2(Lightweight Steel Structural Walls for 2 hours)








Filling compound for construction after heat insulation (AG-200)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Feature 1. Main ingredient of fireproof filling compound structure for facility¡¯s penetration part, used in various specifications.
2. Provides consistent expansion performance in the event of fire with advanced technical skills and high quality.
3. Expands up to 30 times in the event of fire to prevent flame, smoke, and gas by sealing the penetration part tightly.
4. Maintains excellent durability under various circumstances.
¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Pipe size, location, and type 100A floor steel pipe (after heat insulation)
Pipe size, location, and type 200A floor steel pipe (after heat insulation)
Filling material AG-200 (expansion tape thickness 5T+depth 50mm)
Filling material AG-200 (expansion tape thickness 6T+depth 75mm)
Fire prevention sealant AG-1119 thickness 3T
Fire prevention sealant AG-1119 thickness 3T
Thermal insulation material AG-400(25t*200mm)
Thermal insulation material AG-400(25t*400mm)
Location of construction One-sided top construction
Location of construction One-sided top construction
Structure grade C-2(Lightweight foam concrete wall for 2 hours)
Structure grade C-2(Lightweight foam concrete wall for 2 hours)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Pipe size, location, and type 400A floor steel pipe (after heat insulation)
Pipe size, location, and type 200A floor steel pipe (after heat insulation)
Filling material AG-200 (expansion tape thickness 10T+depth 100mm)
Filling material AG-200 (expansion tape thickness 5T+depth 50mm)
Fire prevention sealant AG-1119 thickness 3T
Fire prevention sealant AG-1119 thickness 3T
Thermal insulation material AG-400 (bottom 38t*400mm, top 25t*400mm)
Thermal insulation material AG-400 (25t*400mm)
Location of construction One-sided top construction
Location of construction Double-sided construction
Structure grade C-2 (Lightweight foam concrete wall for 2 hours)
Structure grade A-2 (Lightweight Steel Structural Walls for 2 hours)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Pipe size, location, and type 200A wall steel pipe (after heat insulation)
Pipe size, location, and type 400A wall steel pipe (after heat insulation)
Filling material AG-200(6t*75mm)
Filling material AG-200(10t*50mm)
Fire prevention sealant AG-1119 thickness on both sides 3T
Fire prevention sealant AG-1119 thickness on both sides 3T
Thermal insulation material AG-400(25t*300mm)
Thermal insulation material AG-400(25t*400mm)
Location of construction Double-sided construction
Location of construction Double-sided construction
Location of construction A-2 (Lightweight Steel Structural Walls for 2 hours)
Location of construction A-2 (Lightweight Steel Structural Walls for 2 hours)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Structure of facility¡¯s penetration part Sleeve specification Filling material model name AAG-200 specification (applied thickness)
Metallic pipe floor
150A less than
ST110
2T
Metallic pipe floor
200A
ST120
2T
Metallic pipe floor
AG-400(25t*400mm)
ST130
5T
Metallic pipe floor(fixture)
150A less than
ST1100
5T
Metallic pipe wall
250A more than
ST230
5T
PVC pipe floor
125A less than
PF210
10T
PVC pipe floor
150A more than
PF210
18T
PVC pipe floor(fixture)
125A less than
PF2200
10T
PVC pipe wall
125A less than
PW230
5T
PVC pipe wall
150A more than
PW210
18T
After heat insulation
-
AG200
5T
Video








Dry AD


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Specification 125A~250A, 300A~350A, 400A
Socket 125A~250A(O), 300A~350A(O), 400A(-)
Heat insulation 125A~250A(Uninsulated heat), 300A~350A(25T*600), 400A(Overall heat insulation)






Fireproof filling compound for duct
(AG-DU100)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Feature 1. Specification : 600*15*75T / 600*30*75T / 600*60*75T
2. Provides excellent fire prevention for contraction/expansion.
3. Semi-permanent elastic body that absorbs all external shock.
4. Can be installed easily due to elastic material.
5. Provides excellent soundproofing.
6. Components : Fireproof Filling Compound+Fire Prevention Sealant+Thermal Insulation Material.
Product Groups


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Pipe size, location, and type Duct floor
Pipe size, location, and type Duct wall
Filling material AG-DU100(75mm)
Filling material AG-DU100(75mm)
Fire prevention sealant AG-1119 thickness 3T
Fire prevention sealant AG-1119 thickness on both sides 3T
Thermal insulation material AG-400(38T*400mm)
Thermal insulation material AG-400(38T*400mm)
Location of construction Top and bottom construction
Location of construction Double-sided construction
Structure grade C-2 (Lightweight foam concrete wall for 2 hours)
Structure grade A-2 (Lightweight Steel Structural Walls for 2 hours)


¿¬±¸¼¾ÅÍ¿¡ ´ëÇÑ Á¤º¸ ¸®½ºÆ®
Pipe size, location, and type Duct floor (after heat insulation)
Pipe size, location, and type Duct wall (after heat insulation)
Filling material AG-200 (thickness 11T+depth 50mm)
Filling material AG-200 (thickness 11T+depth 50mm)
Fire prevention sealant AG-1119 thickness 2T
Fire prevention sealant AG-1119 thickness 2T
Thermal insulation material AG-400(25T*400mm)
Thermal insulation material AG-400(25T*400mm)
Location of construction Top and bottom construction
Location of construction Double-sided construction
Structure grade C-2 (Lightweight foam concrete wall for 2 hours)
Structure grade A-2 (Lightweight Steel Structural Walls for 2 hours)